On-Demand Digital Temperature Sensor
|
|
|
The On-Demand Digital Temperature Sensor
|
Like the Flow Sensor, the Digital Temperature Sensor provides real-time feedback to the
Control Panel about the return line temperature. If the loop is hot when a demand occurs
there is no reason to move the water. The city water pressure will move the water toward
the low pressure area (i.e., open faucet) without the need for additional force.
There are 2 benefits to not moving hot water. First hot water in motion tends to lose energy
faster than hot water that is not moving. Second, when the chemicals in water are heated up
they become very corrosive. 90% of all leaks occur on the hot water side of a delivery system.
If is hot, we don't move it.
Our Digital Temperature Sensor allows adjustment of loop temperature in 1 degree F increments.
It also allows us to expand or shrink the differential temperature range (the difference between
when a pump will be turned on and when it will be turned off.
|
|
|
Here are a few of the characteristics of our Digital Temperature Sensor:
|
Temperature setpoint range: -30º to 220ºF
Differential range: 1° to 30°F
Input Voltage: 24vAC
Pilot duty: 125VA at 120/208/240vAC
Sensor: Thermistor, 2" long x 1/4"dia with 8' cable (included)
Control Ambient Temperatures
Operating: -20° to 140°
Storage: -40° to 176°
Ambient humidity: 0 to 95% RH, non-condensing
Enclosure: NEMA 1
Dimensions: 6.52" high x 2.7" wide x 2.48" deep
Agency Approvals: UL listed, file E94419, Guide XAPX, CSA certified, file LR68340, class 4813 02
Relay Output Ratings - NO (NC) 120V
Full load amps 15 (5.8) A
Locked rotor amps 96 (34.8) A
Resistive amps 15 (5.8) A
Horsepower 1 (1/4) HP
|
Why A Simple Aquastat Does Not Work
|
A simple Aquastat has a one setting. Aquastats are used to control the temperature of the water
in a storage tank. Once the temperature level in the storage tank reaches a preset level the
Aquastat tells the boiler to shut off. When the water drops about 5º F below the preset level
the Aquastat will turn the boiler back on.
The 5º F temperature differential is to prevent the boiler from turning on and off every time
the temperature changes by 1º. Unfortunately it is difficult to set the actual desired
temperature very precisely. The dial pictured here is from a standard Aquastat. As you can
see it has gradations every 5º. The accuracy of a typical Aquastat is ± 5º F.
Accurately controlling the loop temperature can increase energy conservation by 10% to 15%.
Our Digital Temperature Sensor eliminates the guess work which means you save more.
|
|